Model:CNME010131/CNME010131plus
Features:
CNME010131:10.4" color LCD screen
CNME010131plus:12.1" color LCD screen
Backlight buttons
Multiple display modes optional: Standard interface,Big font, ECG standard full display,OXY,Trend table,BP trend,Viewbed
Ambulatory blood pressure technology, anti-movement
Special design against high frequency surgical unit,and defibrillation protection
Support SpO2-authorization partner
13 kinds of arrhymia analysis
15 kinds of drug dose calculation
Various languages operating systems
Built-in detachable rechargeable lithium battery 4hours battery life
To connect CMS, other bed observation and software updating with wireless and wired mode
Specifications:
| ECG | |
| Number of Leads | 3 or 5 leads(optional 12leads) |
| User Selectable | I,II,III,aVR,aVL,aVFV(5 Lead);l,ll,III or(3 lead) |
| Gain Selection | x1/4,x1/2,x1 and x2 |
| Frequency Response | Diagnostic:0.05 to 130HZ Monitor:0.5to40HZ Surgery:1-20HZ |
| Heart rate | Adult:15-300bpm/min Neonate/Ped:15-350bpm/min |
| Accuracy | ±1% or ±1bpm |
| Diagnostic Mode | >90 dB |
| Monitor Mode | >100dB |
| Surgery Mode | >100dB |
| ECG Signal Range | ±8mV(p-p) |
| Arrhythmia detection | Available |
| Arrhythmia analysis | 13species |
| Heart Rate | |
| Source User Selectable | Smart,ECG,Pleth |
| Range | Adult:30-250 bpm Neonate/Ped:15-350bpm |
| Accuracy | ±1bpm or ±1% whichever is greater |
| Pulse Oximetry SpO2 | |
| Range | 0 to 100% |
| Resolution | ±3 |
| Accuracy | 70% to 100% range±2% 0 to 69%; undefined |
| Respiration Rate | |
| Rate | Adult:7~120rpm Neo/Ped:7~150rpm |
| Resolution | 1Brpm |
| Accuracy | ±2Brpm |
| Apnea alarm | 10-40s |
| NIBP | |
| Technique | Oscillometric during inflation |
| Cycles(Selectable) | 1,2,3,5,10,15,30,60,90,90,120,180,240,480min |
| Adult range | SYS:40-270mmHg DIA:10-215mmHg MEAN:20-235mmHg |
| Pediatric range | SYS:40-200mmHg DIA:10-150mmHg MEAN:20-165mmHg |
| Neonate Range | SYS:40-135mmHg DIA:10-100mmHg MEAN:20-110mmHg |
| NIBP Storage | 800group |
| STAT model | 5 minutes of continuous reading |
| Resolution | 1mmHg |
| Maximum Mean error accuracy | ±5mmHg |
| Maximum Standard Deviationaccuracy | 8mmHg |
| OverPresure protection | Adult: 300mmHg Pediatric: 240 mmHg Neonate: 150 mmHg |
| EtCo2 | |
| Range | 0-19.7% or 0-150mmHg or 0-20kPa |
| Resolution | 0.1mmHg |
| Accuracy | 0-40mmHg ±2mmHg 41-70mmHg ±5% of reading 71-100mmHg ±8% of reading 101-150mmHg ±10% of reading |
| Balancing gas | environmental,NO2,He |